Is Atlanta tap water safe to drink?
In the latest results, every contaminant we list with a single federal limit was below that limit or action level. Lead was 1.4 ppb at the 90th percentile, below the 15 ppb action level. EPA’s goal for lead is zero. EPA lists 5 health-based violations in the last 10 years, the latest in Apr 2019. See how US tap water compares nationally.
What’s in Atlanta tap water
Latest results from Atlanta DWM’s 2025 report and EPA records. One row per contaminant, with the type of limit in the limit column.
| Contaminant | Result | Limit | Sampled | Source |
|---|---|---|---|---|
| LeadComes mostly from home plumbing, not from the source water. | 1.4 ppb 90th percentile reported to EPA; previous round (2019–2021): 2.4 ppb | 15 ppbAction level · goal 0Drops to 10 ppb on Nov 1, 2027 (Lead and Copper Rule Improvements). | 2022–2024 | EPA SDWIS record, GA1210001 |
| PFOA and PFOS (PFAS)Two “forever chemicals” with a federal limit. | Not detected 12 samples at 3 entry points; none at or above the reporting level (4 ppt) | 4.0 ppt eachLegal limit (MCL) · goal 0Utilities must comply from 2029; EPA proposed 2031 in May 2026. | Apr 2023 – Jan 2024 | EPA UCMR 5 final occurrence data (Aug 2026 release) |
| Other PFASFound among the 27 other PFAS EPA had utilities test. | 4 found PFBA up to 8.3 ppt; PFPeA up to 4.8 ppt; PFHxA up to 4.6 ppt; PFBS up to 4.6 ppt | VariesSet per compound in EPA’s PFAS rule | Apr 2023 – Jan 2024 | EPA UCMR 5 final occurrence data (Aug 2026 release) |
| Total trihalomethanesByproducts of disinfection. | 70.5 ppb Highest locational running annual average; range 18.0–71.4 | 80 ppbLegal limit (MCL) | 2025 | City of Atlanta 2025 Water Quality Report |
| Haloacetic acids (HAA5)Byproducts of disinfection. | 35.5 ppb Highest locational running annual average; range 15.2–37.3 | 60 ppbLegal limit (MCL) | 2025 | City of Atlanta 2025 Water Quality Report |
| ChlorineDisinfectant kept in the pipes on purpose. | 1.13 mg/L Highest monthly average; range <0.07–1.90 | 4.0 mg/LDisinfectant limit (MRDL) · goal 4 | 2025 | City of Atlanta 2025 Water Quality Report |
ppb = parts per billion (µg/L), ppt = parts per trillion (ng/L). The bar shows the result against the limit (black line). Limits: EPA drinking water regulations, PFAS rule, Lead and Copper Rule Improvements. “Not detected” means below the lab’s reporting level, not zero.
EPA violations
EPA’s SDWIS database lists 13 violation records for Atlanta DWM since 1997, 5 of them health-based. All have a return-to-compliance date.
Not listed: 7 older monitoring, reporting or notice records (1997–2015), none health-based.
Shown: health-based violations and everything from the last 10 years. Source: EPA SDWIS record, GA1210001, retrieved Oct 13, 2026.
How hard is Atlanta water?
Atlanta DWM’s 2025 water quality report does not list hardness. Hardness has no federal health limit. A test kit or a lab test measures it at your tap (see how to test water hardness).
What to do with these numbers
Only what the data above points to.
Lead comes from home plumbing
EPA’s goal for lead is zero. Older faucets, lead solder and lead service lines can add lead at your tap. A filter certified to NSF/ANSI 53 for lead reduces it.
Certified to reduce lead. Lead is not necessarily in your water.
All filters compared →Test your own water
Atlanta DWM’s numbers come from its own sampling sites. A certified lab test of your faucet shows lead and copper from your plumbing. How to test your own tap for lead, starting with your water utility.
All water tests compared →